1
| View single post by mhoward | |||||||||
| Posted: Tue Jan 23rd, 2018 10:11 pm |
|
||||||||
|
mhoward Hey look ~ they ~ bounce! Joined: Sun Oct 22nd, 2017
Location: Evansville, USA
Posts: 2770
Status:
Offline
Reputation: ![]() ![]() ![]() ![]() ![]() ![]() Reputation Points: $user_rep
|
Two wires doesn't sound right to me. I believe you need five wires to operate the blend door. There are two specific electric actuators. One would be marked "EATC" or "ATC" the other one "MAN" or "MANUAL". I personally think you have a problem with the wiring. But, if that turns out to not be the case and you need to replace the actuator, see below: To save yourself some grief when changing the actuator, do two things: 1) Tape a heavy string or nylon cord to the 1/4" ratchet handle, then tie it off to the glove box latch. This way WHEN you drop the ratchet down behind the duct, you can pull it back with the cord. 2) When installing that back screw, tie a piece of sewing thread to the screw. Then once the screw is started and maybe half-way in, you can just break the thread and finish tightening it down. If you drop the screw, you can get it back.
____________________ -- Michael 2003 Ranger Edge / Extended Cab / Flareside / 3.0L FLEX / 5r44e Auto / 2WD / 8.8 LS 4:10 / Sonic Blue Pearl So many mods... so little time... |
||||||||
|
| |||||||||